HA216R02

House amplifier, with 204 MHz return path
up to 1218 MHz, gain 40 dB, level CTB, CSO 107/108 dBµV



Ordering number 10582
Specifications

T Y P E

HA216R02

Forward path

Frequency range

258-1218 MHz

Gain

40 dB

Gain adjustment

0...18 dB

Slope adjustment

0...15 dB

Interstage attenuator

-10/-5/0 dB

Interstage equalizer

-10/-5/0 dB

Flatness*

± 1 dB

Noise figure

6 dB

Output level CTB, CSO (EN60728-3)**

107/108 dBµV (34 channels)

Output level Umax., typical**

104 dBµV (120 QAM channels)

Return path

Frequency range

5-204 MHz

Gain, switchable

27/-5 dB

Gain adjustment

0...18 dB

Input attenuator

-10/0 dB

Output equalizer

-10/-5/0 dB

Flatness

± 1.5 dB

Noise figure

7 dB (active, 0 dB input attenuator)

Output level IMD3=60 dB (EN60728-3)***

115 dBµV (active), 121 dBµV (passive)

General

Input and output return loss

≥ 14 dB at 40 MHz; -1.5 dB/oct., but not less 10 dB

Test points****

-20 dB

Power consumption

230 V~ 50/60 Hz  8 W

Operating temperature range

-20° C ÷ +50° C

Dimensions/Weight (packed)

185x91x47 mm/0.7 kg

*       measured 10 MHz after the starting frequency of forward path
**     with 0/5 dB interstage equalizer
***   130 & 132 MHz carriers
**** input test point is bi-directional and could be used as return path output test point;
         output test point is directional and could be used for insertion return path signals